4
General Specifications
Electrical Specifications
Environmental Specifications
AGP-3300∗/3301∗/
3310T/3360T
AGP-3302B AGP-3400∗/3450T
Power Supply
Input Voltage DC 24 V
Rated Voltage DC 19.2 to 28.8 V
Allowable
Voltage Drop
5 ms (max.) 10 ms (max.)
Power
Consumption
26 W (max.) 18 W (max.) 28 W (max.)
In-Rush
Current
30 A (max.)
Voltage Endurance AC 1000 V 20 mA for 1 minute (between charging and FG terminals)
Insulation Resistance DC 500 V 10 MΩ (min.) (between charging and FG terminals)
Physical
Surrounding Air
Temperature
0 to 50 °C
*1
*1 When using a model with a monochrome LCD or a STN Color LCD model in an environment where
the temperature is 40 °C or higher for an extended period of time, the screen contrast level may
decrease from its original level of brightness.
Storage Temperature -20 to +60 °C
Ambient Humidity
10 to 90 % RH (Wet bulb temperature: 39 °C max. - no
condensation.)
Storage Humidity
10 to 90 % RH (Wet bulb temperature: 39 °C max. - no
condensation.)
Dust 0.1 mg/m
3
and below (non-conductive levels)
Pollution Degree For use in Pollution Degree 2 environment.
Comentarios a estos manuales