Attach the Installation Fasteners from Inside the Panel
The following figures show the four(4) fastener insertion slot locations. Insert each fastener's
hook into the slot and tighten it with a screwdriver.
Tightening the screws with too much force can damage the FP's plas-
tic case.
The necessary torque is 0.5N•m.
Depending on the installation panel's thickness, etc., the number of installa-
tion fasteners used may need to be increased to provide the desired level of
moisture resistance.
If the number of the installation fasteners is increased, do not use the FP side
face's middle installation fastener hole. Instead, use the top and bottom holes.
Insertion Slots
Insertion Slots
Top
Bottom
Before installing the FP into a cabinet or panel, check that the installation
gasket is securely attached to the unit.
A gasket which has been used for a long period of time may have scratches
or dirt on it, and could have lost much of its dust and drip resistance. Be
sure to change the gasket periodically (or when scratches or dirt become
visible).
Confirm the Installation Gasket's Positioning
It is strongly recommended that you use the gasket. It absorbs vibration in addition to repelling
water.
Place the FP on a level surface with the display panel facing downward. Check that the FP’s
installation gasket is seated securely into the gasket’s groove, which runs around the perimeter of
the panel’s frame.
Gasket
Rear face
5 Installation
under 4-R2
Panel
Panel thickness
1.6mm[0.06in] to
10mm[0.39in]
Unit: mm [in]
Create a Panel Cut and insert the FP into the panel from the front
301.5 [11.87 ]
+1
0
+0.04
0
227.5
[8.96 ]
+0.04
0
FP
FP
Panel
+1
0
Panel
FP
Installation fastener